(image for) Midmark M11D Ultraclave STERILIZER PM KIT

Midmark M11D Ultraclave STERILIZER PM KIT

Model: MIK080-5894

$142.92

Description

Midmark M11D Autoclave Repair Parts - Guaranteed High Quality

Part #MIK080-5894
OEM Part #002-0504-00 (OEM Part Number is for hte Door & Dam Gasket Only)

STERILIZER PM KIT


Includes

Model This Part Fits: Midmark M11D Autoclaves

So, where's the wire?

The original Midmark Door Gaskets require a wire to hold them in place - ours do not....Because they are not needed with our New & Improved Midmark M11 Door Gaskets!

When you order one of ours, you can throw the wire away (using the wire on one of our door gaskets will cause a leak). All you need is our Door Gasket

View Installation Instructions Below

Notes: Installation Instructions
 


Remove the old door gasket. Clean the gasket groove in the door, and chamber face. For easy installation of the new gasket, use the "South-East-West-North" method (i.e. begin installing the gasket at the bottom of the door, then install the left and right sides and finishing at the top by squeezing in any of the excess making sure that the gasket fits flush).

 

 


Use CAUTION when removing or installing the dam gasket, the door studs can be sharp. To install the door dam, align and place the dam gasket on and over the door studs. The dam must lie flat against the door (refer to the Installation Instructions included with the Dam Gasket (Part #MIG036-5889)

 

 

 

 

Filters


Depending on the age of the machine, you will need to replace either the sintered bronze style Chamber Filter Part #MIF038-5884 or both the mesh style Chamber Filter and Vent Filter See below for instructions.

Chamber Filter (sintered bronze style filter)
Part #MIF038-5884: Remove all trays and the rack from the chamber. Clean chamber then remove the old chamber filter. Install new filter. Reinstall rack and trays.

Chamber & Vent Filters (mesh style filter) Part #MIF062-5886: If the machine has both a Chamber and a Vent Filter, Remove all trays and the rack from the chamber. Clean the chamber, then remove the chamber filter. Install the new filter. Note: The wire mesh filters only sit in place,s simply lift them out with your fingers and drop the new filters in

You must also replace the Vent Filter that serves as a filter for the steam trap/bellows and is located in the vent line to the tee fitting. Reinstall rack and trays.

 

 