Shopping
Autoclave Maintenance
Autoclave Parts
Autoclave Troubleshooting
Dental Equipment Parts
MEDIVATORS
Videos and Animations
EXAM TABLES & CHAIRS
Case Studies
Free Technical Support
Autopsy Saw Parts
Infant Incubators & Warmers
Lab Equipment
Ventilators
Orthopedics & Physical Therapy
Patient Cables & Leadwires
ASPIRATORS AND SUCTION PUMPS
Maintenance Guides
Operational Manuals
Maintenance Tips
Parts Installation Guides
Account Info
Log In
Create Account
Autoclave Maintenance
Tuttnauer Maintenance Guides
Statim Maintenance Guides
Autoclave Parts
Scican Statim
Midmark ® Ritter
Tuttnauer ®
Pelton Crane
Barnstead Sterilizer
Kavoklave
Midmark Ritter
NAPCO
AMSCO
PRESTIGE 2100
Ritter - Castle
Spectroline
S.S. White
Vernitron
Autoclave Cleaning Products
MDT Harvey Mediclaves
Autoclave Repair Supplies
Autoclave Repair Special Tools
Autoclave Troubleshooting
Prestige 2100
Statim G4 Troubleshooting
tuttnauer temp
STATIM DETAILED TROUBLESHOOTING
VernitronTroubleshooting
NAPCO Troubleshooting
How To Test Heating Elements
Midmark Troubleshooting
Tuttnauer Troubleshooting
STATIM TROUBLESHOOTING
Documents & Guides
Pelton Crane Troubleshooting
Troubleshooting Guides
AMSCO 3000 BASIC TROUBLESHOOTING
AMSCO 900 & 901
Delta XL Troubleshooting
Castle Table Top Troubleshooting
CHEMICLAVE 5000 TROUBLESHOOTING
Kavoklave
Steam Trap Troubleshooting
Dental Equipment Parts
Dental Chair Parts
Dental Handpieces & Parts
DENTAL ULTRASONIC SCALERS
Miscellaneous
Dental Compressor Parts
Dental Delivery Systems
Dental Film & X-Ray Processors
Dental Light Parts
Dental Vacuum Parts
Dental Water Control Parts
MEDIVATORS
Medivator Advantage Plus
Medivator DSD-201
Medivator CER Optima
Medivator DSD-91E
Medivator DSD Edge
Medivator SSD-102
More
Videos and Animations
EXAM TABLES & CHAIRS
Case Studies
Free Technical Support
Autopsy Saw Parts
Infant Incubators & Warmers
Lab Equipment
Ventilators
Orthopedics & Physical Therapy
Patient Cables & Leadwires
ASPIRATORS AND SUCTION PUMPS
Maintenance Guides
Operational Manuals
Maintenance Tips
Parts Installation Guides
About Us
Blog
Home
›
Autoclave Parts
›
Ritter - Castle
›
777 Parts Installation Guides
› Caslte 777 Air Vent Bellows Installation Instuctions
Caslte 777 Air Vent Bellows Installation Instuctions
How To Replace The Castle 777 Air Vent Bellows Assembly
Removing The Old Bellows
Remove The Liner From The Chamber
A.
Older Models:
Remove the four (4) hex head screws from the back of the shell to release the liner
B.
Newer Models:
Remove the 6-32 Screw from the inside of the liner that secures it to the back of the chamber. Then carefully remove the liner from the retaining guide, extending down from the shell in the rear of the chamber
Remove The Old Bellows assembly from the liner
Installing The New Bellows
Remove the nut from the stem of the new bellows assembly
Screw the new bellows assembly stem completely into the liner from the outside, and hand tighten the nut on the inside
Replace The Chamber Liner
A.
Older Models:
Be Sure to place the four (4) special washers under the heads of the four (4) hex head screws
Caution:
Tighten the four (4) screws snugly so that no leakage occurs around the washers. Overtightening the screws will strip the threads
B.
Newer Models:
Place the liner in the chamber so that the retaining guide, extending down from the top of the chamber,
enters the slot in the liner. Replace the 6-32 screw tha holds the liner in place
Click Here
For The Bellows Adjustment Procedures
By Purchasing The
Castle 777 Air Vent Bellows Assembly
You Need From Us, You Can Rest Assured You Are Getting The Highest Quality Parts Available